Sign In | Join Free | My himfr.com
Home > Air Dry Coolers >

Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System

    Buy cheap Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System from wholesalers
     
    Buy cheap Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System from wholesalers
    • Buy cheap Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System from wholesalers
    • Buy cheap Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System from wholesalers
    • Buy cheap Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System from wholesalers
    • Buy cheap Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System from wholesalers
    • Buy cheap Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System from wholesalers
    • Buy cheap Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System from wholesalers
    • Buy cheap Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System from wholesalers

    Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System

    Ask Lasest Price
    Brand Name : Shenglin
    Model Number : D Series
    Certification : CE certification
    Price : 600~31005 USD/Unit
    Payment Terms : T/T, Western Union
    Supply Ability : 50~100 units per month
    Delivery Time : 35~45days
    • Product Details
    • Company Profile

    Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System

    Hydrophilic Aluminum Fin Glycol-Water Cooler Closed Loop Cooling Systems Multiple Circuits


    Dry cooler vs wet cooling tower:

    Dry coolers are heat-transfer devices that use air to remove excess heat. Usually, a dry cooler presents a heat exchanger (usual fin heat exchanger) and fans. The fans are responsible for directing the airflow through the heat exchanger. Here, the fluid (it can be water or another solution) is cooled and circulated back into the system.


    For a dry cooler to be efficient, the air temperature needs to be cooler than the water (or any other glycol solution) in the system. This explains why, for example, dry coolers work better in cold climate regions (while wet cooling towers are more efficient in hot and dry climates). Dry coolers are not affected by air humidity, on the contrary to wet cooling towers.


    Dry coolers have a limited cooling capacity, compared to wet cooling towers: the first one only brings the water temperature down to the ambient temperature (additional cooling can be achieved in other ways), while the latter can bring the water temperature up to 5 degrees down the ambient temperature.


    Dry cooler features:

    Air discharge direction
    Performance ranges

    Cooling capacity: from 5 to 649 kw

    Air volume: from 2828 to 263503 m3/h

    Sound pressure level: from 31 to 69 dB A(10m)

    Dry coolers:customized on demand

    High efficiency heat exchanger

    Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.

    Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).

    Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

    Fan

    Only choose low specific energy consumption fans.

    Fan nozzle designs for maximum air flow and air throw.

    Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.

    Motor: protection class IP 54 and insulation class F.

    Voltage:400V/3N/50Hz

    Air separator for each fan.

    TestingHeat exchangers are supplied clean and tested at a pressure of 30 bars
    Options

    Coil design refrigerant: water, oil, glycol.

    Multiple circuits.

    Sub-cooling circuits.

    Stainless steel or aluminum casing.

    Coated aluminum or copper fins.

    Explosion ploof motor.

    Customized fin spacing.



    Dry Cooler technical parameter

    Dry cooler D1 series parameter(fin space 2.1mm)

    Type

    D1-166-

    4x630

    D1-211-

    6x630

    D1-247-

    6x630

    D1-286-

    8x630

    D1-334-

    8x630

    D1-360-

    10x630

    D1-415-

    10x630

    D1-502-

    12x630

    D1-565-

    14x630

    D1-649-

    16x630

    CapacityWater35℃ outdoor temp.Inlet45℃,KW165.92211.36247.3286.15334.49359.72415.31502.25565.18649.48
    outlet40℃Y134.59176.00200.45238.3270.889298.57335.225405.20459.3527.59
    20% GlycolInlet45℃161.32205.08240.46280.05327.72351.3406.48493.40554.21638.44
    outlet40℃Y130.96170.87195.07233.18265.64291.81328.48398.45450.87519.13
    MediumWater flowM3/h29.003743505863728898113
    Pressure dropkPa50704797959270979695
    Air flowM3/h67455109723101185146293134908179502164442197326230584263503
    Y512658366176900111544102528136437124680149612174710199665
    Fan motorPhase3333333333
    W1100165001650022000220002750027500330003850044000
    Y700105001050014000140001750017500210002450028000
    A20.430.630.640.840.851.0051.0061.2071.4081.60
    Y12.0018.0018.0024.0024.0030.0030.0036.0042.0048.00
    FanNo X φ

    2X2

    X630

    2x3

    x630

    2x3

    x630

    2x4

    x630

    2x4

    x630

    2x5

    x630

    2x5

    x630

    2x6

    x630

    2x7

    x630

    2x8

    x630

    Sound pressure leveldB(A)64666667676868686969
    Y10m57595960606161616262
    DimensionLmm29304230423055305530683068308130943010730
    Wmm2100210021002100210021002100210021002100
    Hmm1070107010701070107011201120112011201120
    Amm--------------------
    Bmm1340134013401340134013401340134013401340
    Cmm1300130013001300130013001300130013001300
    Dmm640640640640640640640640640640
    Inlet φmm3”3”3”DN100DN100DN100DN125DN125

    2X

    DN125

    2X

    DN125

    Inlet φmm3”3”3”DN100DN100DN100DN125DN125

    2X

    DN125

    2X

    DN125

    Product weight(empty)kg6586897601105127013201420158418482112

    Application:

    Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, sloar system, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.


    Shenglin dry cooler selection software example:


    Packing:

    Hydrophilic Aluminum Fin Closed Loop Glycol Cooling SystemHydrophilic Aluminum Fin Closed Loop Glycol Cooling System
    Hydrophilic Aluminum Fin Closed Loop Glycol Cooling SystemHydrophilic Aluminum Fin Closed Loop Glycol Cooling System

    Some reference:

    Dry cooler case
    Case 1: used in chemical plant.

    Case 2: used in chemical plant. Refrigerant: ethylic acid(flow: 372 ton/h)


    Hydrophilic Aluminum Fin Closed Loop Glycol Cooling SystemHydrophilic Aluminum Fin Closed Loop Glycol Cooling SystemHydrophilic Aluminum Fin Closed Loop Glycol Cooling SystemHydrophilic Aluminum Fin Closed Loop Glycol Cooling System
    Case 3: used in communication station as air conditioner outdoor unit in China.

    Case 4: used in communication station as air conditioner outdoor unit


    Hydrophilic Aluminum Fin Closed Loop Glycol Cooling SystemHydrophilic Aluminum Fin Closed Loop Glycol Cooling System
    Quality Hydrophilic Aluminum Fin Closed Loop Glycol Cooling System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Shenglin M&E Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)